This post is machine-translated. The original post in german language can be found here.

Error "Invalid object name" in form Security entry point permissions

When using the form "Security entry point permissions" the following error may occur when changing the field "Type":

Invalid object name.

The cause is that the tool tries to create an object in the AOT having the user id as part of its name. When this user ID contains characters that are not allowed in an object name (for example dashes), the error is thrown.

Simplest workaround: Using another user.

These post applies to following version:
Dynamics AX 2012

 
 

 

 
 
 